Sensepeek 4013 SP100 Oscilloscope Probe (100 MHz)
Description
This passive high-impedance oscilloscope probe is suitable for most oscilloscopes with a 1 MΩ input impedance.
*The probes can continue to measure above the rated bandwidth but with decreased signal, the probe will reach the f3dB limit above the rated bandwidth. The probe has a flatness of ±0.5dB over the first 1/3 of the bandwidth and less than ±3dB over the specified bandwidth.
SP100 | SP200 | |
---|---|---|
Bandwidth >= f3dB (MHz)* | DC to 100 MHz | DC to 200 MHz |
Rise time (ns), alculated | 3.2 | 1.75 |
Attenuation Ratio | 10:1 | |
Input Resistance (MΩ), ± 2% | 10 | |
Input Capacitance (pF) | 10 - 14 | |
Full-scale measurement range | Voltage: +/-60 V DC, 30 V AC RMS, +/-42.4 V pk max. | |
Overvoltage protection(voltage that will not damage) | 200 V DC + peak AC | |
Compensation Range (pF) | 15 - 45 | |
Cable length with BNC | 1.1m | 0.8m |
Operating Environment, Max. altitude 2 km | -20 to +60 °C, 0 to 80% RH | |
Storage Environment, Max. altitude 15 km | -20 to +60 °C, 0 to 80% RH | |
Probe tip diameter (mm) | 0.5 | |
Pollution Degree | 2 (As defined in IEC 61010-031. Only non-conductive pollution. Occasionally, however, a temporary conductivity caused by condensation must be accepted.) | |
RoHS and REACH compliant | Yes |
Shipping weight: | 0.13 Kg |